Technical data
| Unit | TURBOVAC 90 iR | TURBOVAC 250 iR | TURBOVAC 350 iR | TURBOVAC 450 iR | TURBOVAC 850 iR | TURBOVAC 950 iR | TURBOVAC 1350 iR | TURBOVAC 1450 iR | |
| High vacuum connection | DN | 40 ISO-KF, 63 ISO-KF, 63 CF | 100 ISO-K, 100 CF | 100 ISO-K, 100 CF | 160 ISO-K, 160 CF | 160 ISO-K, 160 CF | 200 ISO-K, 200 CF | 200 ISO-K 200 ISO-F 200 CF | 250 ISO-K 250- ISO-F 250 CF |
| Fore vacuum connection | 16 KF | 16 KF | 25 KF | 25 KF | 25 KF | 25 KF | 40 KF | 40 KF | |
| Pumping speed | |||||||||
| N2 | l x s | 90 | 225 | 290 | 430 | 720 | 900 | 1,250 | 1,380 |
| Ar | 83 | 210 | 260 | 400 | 655 | 840 | 1,150 | 1,280 | |
| He | 90 | 250 | 360 | 440 | 850 | 925 | 1,350 | 1,390 | |
| H2 | 78 | 210 | 350 | 420 | 755 | 770 | 1,150 | 1,210 | |
| Gas throughput | |||||||||
| N2 | mbar x l x s | 8.5 | 2.6 | 4.5 | 4.5 | 6 | 6 | 16 | 16 |
| Ar | 3.5 | 1.9 | 3.0 | 3.0 | 3.6 | 3.6 | 12.5 | 12.5 | |
| He | 11 | 4 | 8.0 | 8.0 | 12 | 12 | 18 | 18 | |
| H2 | 11 | 6.5 | 8.0 | 8.0 | > 15 | > 15 | 10 | 10 | |
| Noise level | |||||||||
| With water cooling | dB(A) | – | 44 | 44 | |||||
| With convection cooling | < 41 | < 41 | < 44 | < 44 | < 40 | < 40 | – | – | |
| With radial air cooler | < 44 | < 44 | < 47 | < 47 | < 55 | < 55 | – | – | |
| With axial air cooler | < 49 | < 49 | < 49 | < 49 | < 49 | < 49 | – | – | |
| Maximum bake-out temperature of the CF version, water cooled | °C | 100 | |||||||
| Purge gas flow | mbar x l x s | 0.4 | |||||||
| sccm | 24 | ||||||||
| Purge gas connection | inch | G 1/8 | |||||||
| Venting connection | |||||||||
| Compression ratio | |||||||||
| N2 | 1 x 108 | 1 x 1011 | 1 x 1011 | 1 x 1011 | > 1 x 1011 | > 1 x 1011 | 1 x 108 | 1 x 108 | |
| Ar | 1 x 108 | 1 x 1011 | 1 x 1011 | 1 x 1011 | > 1 x 1011 | > 1 x 1011 | 1 x 108 | 1 x 108 | |
| He | 1 x 106 | 1.5 x 107 | 1.5 x 107 | 1.5 x 107 | 1.3 x 108 | 1.3 x 108 | 1 x 105 | 1 x 105 | |
| H2 | 2 x 104 | 2 x 105 | 1 x 105 | 1 x 105 | 4.4 x 106 | 4.4 x 106 | 2 x 104 | 2 x 104 | |
| Ultimate pressure with 2-stage oil- sealed rotary vane pump ISO-K / CF | mbar | < 8 x 10-8 / < 5 x 10-10 | < 8 x 10-8 / < 5 x 10-10 | < 8 x 10-8 / < 5 x 10-10 | < 8 x 10-8 / < 5 x 10-10 | < 3 x 10-8 / < 3 x 10-10 | < 3 x 10-8 / < 3 x 10-10 | < 7.5 x 10-9 / < 1 x 10-9 | < 7.5 x 10-9 / < 1 x 10-9 |
| Maximum permissible fore vacuum pressure for N2 | mbar | 14 | 11 | 10 | 10 | 12 | 12 | 4 | 4 |
| Operating speed | rpm | 72,000 | 72,000 | 60,000 | 60.000 | 49,200 | 49,200 | 42,000 | 42,000 |
| Approximate run-up time (with 3 m cable) | min | 1.5 | 1.5 | 3.5 | 3.5 | 4.5 | 4.5 | 4,5 | 4.5 |
| Maximum power consumption | W | 240 | 240 | 240 | 240 | 500 | 500 | 500 | 500 |
| Type of protection | IP 40 | ||||||||
| Ambient temperature during operation | °C | +5 to +40 | |||||||
| Ambient temperature storage | °C | -15 to +70 | |||||||
| Standard cooling | Convection | Convection | Convection | Convection | Convection | Convection | Water | Water | |
| Optional cooling | Air or water | Air or water | Air or water | Air or water | Air or water | Air or water | Water | Water | |
| Cooling water connection | Plug connection for 6 x 1 hose / alternatively G 1/8 inch screw-in thread | ||||||||
| Cooling water consumption | l / h | 30 to 60 | 30 to 60 | 50 to 100 | 50 to 100 | 50 to 100 | 50 to 100 | 50 to 100 | 50 to 100 |
| Permissible cooling water pressure | bar(g)* | 3-6 | 3-6 | 3-6 | 3-6 | 3-6 | 3-6 | 6 | 6 |
| Permissible cooling water temperature | °C | 15 to 35 | |||||||
| Weight: KF-40 / ISO-K / ISO-F / CF | kg | 3.1 / 4.0 / 8.0 | 4.0 / 6.6 | 7.5 / 11.5 | 7.5 / 12.5 | 14.6 / 19.6 | 15.4 / 21.7 | 23.5 / 24.3 / 33.3 | 24.4 / 25.5 / 34.2 |
* bar(g) = bar (gauge) is overpressure, for example, atmospheric pressure = 0 bar(g)